How to estimate usable capacity from field data ​

This page is for technical readers who want the research behind the battery health estimate. To use the dashboard and understand its numbers, read Battery health instead; you do not need anything on this page.

This note is the evidence behind the usable-capacity sensor. It records what the published methods need, what other products actually do, and what the Marstek Open API can support. How to turn the dashboard and the cards on is Battery health. The calculation, the store, and the limits are under the hood on that same page.

Home Assistant's sensor classes are cited there from Core 2026.9.3. There is no Marstek document online for the local API; the field list is the Open API note in this repo.

What "usable capacity" means here ​

Plett defines cell total capacity as the charge that can be extracted from a full cell, and treats it as the quantity behind state of health. The estimator in his 2011 paper is

text
y = Q * x

where x is the change in state of charge between two times and y is the charge moved in that interval. Q is the capacity. See Plett, "Recursive approximate weighted total least squares estimation of battery cell total capacity", Journal of Power Sources 196 (2011) 2319–2331 (author PDF, doi:10.1016/j.jpowsour.2010.09.048).

That is the same relation this integration uses, in watt-hours instead of ampere-hours, because the Open API gives power and watt-hour nameplate rather than a DC current sensor. Q here is watt-hours per 100 points of reported state of charge. It is not reduced by the SYS depth-of-discharge setting. Marstek Capacity Monitor scales a full discharge to that band, so its number is the energy inside the band rather than Q.

Methods, and whether we can run them ​

Coulomb counting between state-of-charge points ​

Integrate current (or, for us, power) between two state-of-charge readings and divide by the state-of-charge fraction. This is the field form of Q = y / x. It needs no cell model. It does need the state of charge at the two ends to mean the same scale, and it needs the integral not to have large holes.

Plett's warning on this method is the one that matters here. Ordinary least squares treats only y as noisy. State of charge is also noisy, so the fit is biased, and total least squares is the regression that allows noise on both axes. He also warns that the state-of-charge input must not itself be a coulomb count that uses the capacity being estimated: that loop does not converge. A voltage-based or Kalman state of charge that was computed with a fixed nameplate is the input he wants. On LFP he reports that even a sigma-point Kalman filter, which is much more than an open-circuit-voltage lookup, still has typical state-of-charge errors of about 3–5 percent, because the open-circuit-voltage curve is flat (same paper).

We implement the coulomb-counting ratio, not weighted total least squares. The Open API does not give the state-of-charge error variance or the power error variance that the weighting needs, and a recursive update would let one bad window pull the value. A median of complete windows is the robust version we can justify from the samples we have. The spread of those windows is reported twice, each direction against its own median and the larger direction kept. run_scatter_pct is the median absolute deviation as a percentage of the median: half the windows lie within it. spread_wh is the full range relative to the median, times the published value. Neither counts the gap between the charge and discharge medians, which in the geometric mean is an efficiency offset rather than disagreement. Both are observed spreads, not confidence intervals. A confidence interval would pretend we know the noise variances Plett's estimator requires.

Round-trip efficiency ​

The integral we have is AC power at the inverter port, not DC current at the cells. Charge and discharge therefore need an efficiency. If the same one-way efficiency η is wrong by the same amount in both directions, the discharge estimate scales by η_true / η_assumed and the charge estimate scales by η_assumed / η_true. The geometric mean of the two is the capacity, and the assumed factor drops out. That is ordinary algebra on Plett's y = Q x once each y has been converted from AC watt-hours with the same factor. It is why the sensor switches to the geometric mean of the charge median and the discharge median once each direction has three windows. Until then it publishes the median of whichever direction already has three windows, and does not pool the two.

The ratio of those medians is the round trip the assumption implies:

text
η_discharge × η_charge ≈ η_assumed² × (discharge median / charge median)

With η_assumed at 0.93 on both paths, equal medians mean a round trip of 0.865, which is 0.93². The sensor exposes that as implied_round_trip_efficiency, once each direction has three windows. It is not a measured efficiency. A different real charge and discharge efficiency leaves sqrt(η_discharge / η_charge) on the geometric mean. A steady self-consumption that the reported watts leave out pulls the two medians apart instead: discharge reads low, charge reads high. At equal power the two cancel in the geometric mean, and at unequal power a residual remains (see Expected error). The implied round trip carries both errors.

Until one direction has three windows, nothing is published. A single direction still uses the fixed one-way factor 0.93 from the mock pack model. That number is not a measurement on Marstek hardware.

PV charging power is not that AC port. On Venus A and Venus D, ES.GetStatuspv_power and PV.GetStatus are MPPT charging power (Open API note, sections 3.5 and 3.6.1). The derived battery reading is pv_power - ongrid_power - offgrid_power. Running the 0.93 factor over the whole reading multiplies PV watt-hours by 0.93 even though they never entered the inverter, which pulls a PV-only charge window down by about 7%. The estimator applies the factor to battery_power + pv_power only, then subtracts pv_power. Venus E 3.0 reports pv_power 0, so the expression collapses to the AC formula. A firmware that sends bat_power is left on the AC formula too: the note does not say that field is DC, and changing it would move those windows.

Victron's battery monitor is the clearest manufacturer statement of the same physics, on ampere-hours rather than watt-hours. The SmartShunt manual says the monitor integrates current, that effective capacity depends on discharge rate and Peukert's exponent, and that more ampere-hours must be charged than can later be discharged. For LiFePO4 it tells the installer to set the Peukert exponent to 1.05 unless the supplier says otherwise, and the charge efficiency factor to 99 percent. A Peukert exponent of 1.00 turns the rate correction off. Charge efficiency of 95 percent means 10 Ah must be supplied to store 9.5 Ah (SmartShunt manual, PDF, Peukert chapter, settings chapter).

Those 99 percent and 1.05 figures are for a DC shunt on lithium cells. They are not the AC round trip of a Marstek inverter plus pack, so they are not copied into the estimator. They are the reason a C-rate correction is not invented here either: at the currents these packs actually use, an exponent of 1.05 is a small effect, and we do not have the cell's rated-hour current to apply Peukert's formula honestly.

Incremental capacity and voltage methods ​

Incremental capacity analysis plots dQ/dV against voltage and reads fade from the shift of those peaks. It needs a slow, high-resolution voltage sweep and the charge moved along it. Marstek's fast poll has no cell voltage and no pack voltage. Open-circuit-voltage state of charge has the same gap, and on LFP the curve is flat enough that Plett treats voltage-only state of charge as a poor input. These methods are not implementable on this API.

Kalman filters and recursive least squares ​

A Kalman filter of capacity, or recursive least squares on y = Q x, is the online form of the same fit. Plett's preferred state of charge is itself a sigma-point Kalman filter on a cell model that includes voltage (2002 EVS paper, author PDF). A later coulomb-counting paper updates capacity with recursive least squares between two state-of-charge points, and it resets those points from open-circuit voltage after the current has been zero for 25 minutes (Energies 2020, 13(7), 1811). Without a voltage measurement there is nothing for either filter to correct against, so the state of charge we have stays the BMS percentage. Recursive least squares on our windows would also be less robust than a median: one glitched window has a permanent vote until it is forgotten. The sensor keeps a 21-window median instead.

Temperature ​

Usable energy falls when the pack is cold. The fast poll does not carry cell temperature. Bat.GetStatus does (bat_temp), and this integration leaves that call off unless a diagnostic entity is enabled, because it is suspected of resetting some devices (Open API note). Applying a temperature coefficient we have not measured on these cells would invent a correction. Cold sessions therefore read low. That shows up as spread between windows, not as a silent adjustment.

Cycle counting ​

A cycle count is not a capacity. Sonnen exposes cyclecount from its own battery endpoint; EVCC and the sonnen JSON API expose user state of charge and, on /api/v2/battery, full charge capacity in ampere-hours as the BMS reports it (sonnen status fields as published by community API notes, EVCC sonnen template). The Marstek Open API has no cycle counter. Counting only the windows that moved at least 20 state-of-charge points would miss every smaller cycle, so the sensor does not publish a cycle count.

Outliers ​

A window outside 300–30,000 Wh, or outside 15–135 percent of the nameplate when one is known, is dropped. Inside that band the median is the outlier rule. A sigma clip around the current estimate would also clip a real step down in capacity, which is the trend the sensor exists to show. The observed range of the windows that remain, within each direction, is spread_wh, and a wide scatter lowers the confidence instead of dropping windows.

What other products do ​

They almost all display a capacity the battery or the installer already stated. They do not estimate fade from power and state of charge.

ProductWhat it publishesSource
Victron SmartShuntState of charge from a shunt. Battery capacity is a setting in Ah, not a measured fade.SmartShunt manual
Tesla Powerwallbattery_nominal_full_pack_energy: available energy when full at 25 °C, "affected by temperature, degradation, etc." Tesla's own BMS figure. The warranty tracks that against 13.5 kWh (70 percent at 10 years for the common US terms).Tesla Energy Library, battery signals, Powerwall warranty (US)
SonnenUser state of charge (USOC) from the local JSON API. Full charge capacity (fullchargecapacity, Ah) and cyclecount come from the BMS on /api/v2/battery. EVCC's template reads USOC and takes capacity as a configuration value in kWh.sonnen JSON API fields as mapped by the Home Assistant integration, EVCC template, EVCC capacity parameter
Home Assistant PowerwallThe core integration's battery capacity sensor reads the gateway's own full-pack energy. That is the same BMS figure as battery_nominal_full_pack_energy, not a coulomb count done in Home Assistant.Powerwall integration, Tesla Energy Library
TeslaFiBattery degradation report is rated range at 100 percent, or range divided by the ending state of charge when the charge stopped short of 100 percent. TeslaFi's own note is that state of charge is a whole number, so an incomplete charge does not know whether it ended at 79.1 or 79.9 percent, and those charges are left out of the report.TeslaFi support: how degradation is calculated, completed charges
RecurrentRange Score is expected range today divided by observed range when new for that configuration. Recurrent says a lab capacity in kWh is not what the car reports, and that an exact state of health from outside the vehicle is not available.Range Score, why an exact health figure is not available
This integrationNo BMS state of health exists on the Open API, so the sensor is the coulomb-counting estimate below.Open API note

Marstek Capacity Monitor ​

Marstek Capacity Monitor is a community Home Assistant integration that does estimate fade from state of charge and power. Its method, from its how-it-works page and calc.py:

  • It integrates DC battery power from any source (ESPHome, Modbus or another integration), and warns when you pick an AC power sensor because AC includes conversion losses.
  • It counts only full discharges, from 95% or higher to 15% or lower, found as swings with a 3-point hysteresis. It publishes the median of the last three in the past year, scaled to the depth-of-discharge band.
  • It ignores partial discharges because, in its authors' words, one percent near the bottom delivers more kWh than one near the top. That is their observation; it is not backed by a measurement in that repository.
  • It compares the result with a line of 80% after 6,000 cycles, counting cycles from its own DC discharge integral.

What this integration takes from it, and what it does not:

IdeaHereWhy
Long windows make whole-percent error smallTaken in another form: windows start and end on a state-of-charge stepA full-discharge-only rule would rarely publish on a house battery that cycles 20–60 points a day, and our AC integral already needs both directions for the geometric mean.
DC power onlyNot possible on the Open APIThe Open API has no DC current or voltage. The 0.93 factor and the geometric mean are the AC substitute. This integration's battery_power entity is that AC reading (derived from the power balance when bat_power is omitted). It must not be used as Capacity Monitor's DC input.
Band dependenceNot correctedWe have no measurement of energy per percent by band on Marstek packs. Windows from mixed bands go into one median.
Cycle line and warranty coloursNot takenThe Open API has no cycle counter, and an AC integral is not a DC cycle count. See Cycle counting.
Automatic power sign detectionNot neededThe integration owns the sign of battery_power.

What the Marstek signals are actually worth ​

Fast poll, default every 30 seconds, with a default 5 second gap between the calls inside the cycle. No extra request is added for this sensor.

SignalGranularity and trustUsed?
bat_socState of charge. Captures and the mock report whole percents. A window that started on an arbitrary poll could be a point off, about 5 percent on 20 points, so windows start on the first poll after the percentage changes. It is the BMS's own percentage. If that percentage is stretched to a fixed nameplate, the ratio Q = y / x recovers the stretched scale, not chemical fade the BMS is hiding. Plett's circular-dependence warning applies if the BMS coulomb-counts this percentage with its own capacity.Yes. It is the only state-of-charge signal.
Battery powerWatts, integer on the wire. Venus E 3.0 and several later firmwares omit bat_power; the integration then uses pv_power - ongrid_power - offgrid_power, which for a pack with no DC input is the inverter AC port. On Venus A and D the same expression mixes DC PV watts with the AC port; the capacity estimator derates only the AC port. Sign: positive discharges. This entity is not a DC shunt reading and must not be fed to a tool that integrates DC battery power.Yes.
ES.GetModeOperating mode. Used only to discard a window that changes mode. A poll that omits the mode is not treated as a change.Yes, as a gate.
bat_capNameplate watt-hours where the firmware profile says so. Venus E captures show 5120 Wh. Venus E mini stores remaining energy in this field, so it is not a nameplate and state of health is not created. It is not the estimate.Nameplate only.
Lifetime grid, PV, and load energyHouse and inverter meters. Encoding changes with firmware (Wh versus 0.01 kWh, PV1 deciwatts). They do not measure charge into the cells.No.
Bat.GetStatusRemaining and rated watt-hours, temperature, charge flags. BMS bookkeeping. The call is off by default and is suspected of resetting some devices.No.
Cell voltage, pack voltage, cycle count, BMS state of healthNot in the Open API.Not invented.

Granularity, per family ​

None of these builds expose a second, finer state of charge. The parser forwards bat_soc as the device sent it. Captures and the mock both use whole percents (int in the mock's get_state). A fractional percent has not shown up in a capture, so the estimator treats one count as one point. Power fields on the wire are whole watts. The mock reports round(watts).

bat_power is the exception that is usually missing. The field string is in the HMG-50 Control 153 table only. It is absent from HMG-50 155/156 and from the archived VNSE3-0, VNSA-0, and VNSD-0 images, and the Venus E 3.0 firmware 150 LAN capture omitted it (tools/mock_device/firmware_quirks.py, Open API note section 4.3). When it is absent the integration derives it:

text
bat_power = pv_power - ongrid_power - offgrid_power

with the API sign (positive charges). For a Venus E with no PV that is the inverter AC port, which is what the estimator integrates. For Venus A and Venus D it is an energy balance, so a wrong PV wattage becomes a wrong battery wattage. Channel 1 is still deciwatts on every firmware checked so far, including 150.9 and 151 (issue #57); the parser scales it to watts before that balance. A tenfold PV mistake would land outside the 15–135 percent nameplate band and be dropped, rather than published as capacity.

Lifetime energy is the untrustworthy counter. Venus A up to 148 stores solar energy in Wh. From Venus A 148.7 and Venus D 149 on, and on every known family from 150, it is 0.01 kWh (Open API note, section 4.2, issues #35 and #57). EM lifetime energy is 0.1 Wh from Control generation 148 when EM.GetStatus is served (#174). Grid totals on the Venus E 150 capture were Wh. Those counters are not used.

Nameplate bat_cap on Control firmware is the rated pack (Venus E 150: 5120 Wh; Venus A: 2080 Wh). Venus E mini, including VNSEM-0 301, puts remaining energy in that field (1916 Wh at 95 percent, rated 2009 Wh, issue #86), so state of health is not created there. A bat_cap of 0 is treated as a silent BMS, not as an empty pack, except on the mini where 0 can be a drained pack.

Update rate is the fast poll: 30 seconds by default, with 5 seconds between the calls in the cycle, both configurable. A 20-point window at a steady power therefore contains on the order of minutes of samples, not a high-rate current trace. Bat.GetStatus would add temperature and the BMS remaining/rated pair, and it stays off because it is suspected of resetting some devices (issue #14).

HMG-50 (Venus C, and Venus E 2.0 which this integration does not set up) shares one Wi-Fi receive channel with its meter client, so many Open API datagrams are lost (issue #82). A gap over the limit (180 seconds at the default poll, longer only when the configured fast interval itself exceeds that) aborts the open window. That makes HMG-50 a poor source of clean windows, which is another reason the sensor does not add traffic.

What is trustworthy enough to integrate: ES.GetStatus bat_soc, the derived or reported battery watts after the parser's sign flip, and ES.GetMode as a gate. What is not: lifetime energies, Bat.GetStatus bookkeeping, GetMode's CT zeros (the Venus E 150 capture showed ct_state=0 while EM.GetStatus showed a live meter), and any field the API does not have.

The method that those constraints allow ​

  1. Start a window on the first poll after the whole-percent state of charge changes. Keep it only while direction, mode, and the sample gap stay clean, and state of charge moves at least 20 points across at least four samples. Power has to stay at or above 150 W. A same-sign dip below that, for at most two polls, stays in the window; a third dip, or any opposite-sign reading, ends it. A window whose average is still under 150 W is not published, because the fixed 0.93 factor does not describe the inverter there. End the window when state of charge jumps further than that poll's watts can move the nameplate, with a floor of two points and one point of slack. A step equal to that limit stays. Such a step waits up to two polls: if one of them is nearer the level before it than the level after it, and within that limit of the earlier level, the step was a glitched reading and is dropped without ending the window; if the third poll stays near the new level, it ends the window. A step that lands back near the level before the previous poll is the far side of a spike that rose under the floor: it stays an ordinary move, and the spike's reading is set back to the earlier level. Over a segment longer than 120 seconds the endpoint watts cannot bound a load spike between the polls, so a step there ends the window without counting as a BMS correction. The gap limit is 180 seconds, or the configured fast interval plus 150 seconds when that is longer. A poll that did not get ES.GetStatus is a hole, not a sample, and it does not discard the open window. The next fresh sample is still subject to the gap limit.
  2. Convert the AC port with one-way efficiency 0.93 (discharge divides, charge multiplies). On a derived reading, subtract PV watts after that conversion so PV energy is not derated. Capacity is that DC energy divided by the state-of-charge fraction. That is watt-hours per 100 points, not watt-hours inside the depth-of-discharge setting.
  3. Drop a window outside the physical band above.
  4. Publish one direction's median once that direction has three windows. Each direction keeps its newest 21, so one session cannot crowd the other out. Do not pool a short run in the other direction into that median.
  5. When both directions have three windows, replace that median with the geometric mean of the two direction medians.
  6. Publish state of health only against a real nameplate. Stay unknown until step 4 has something to publish. Store each window's end points, average power, duration, mode, and PV share. Expose the two medians, and the implied round trip once each direction has three windows, as sensor attributes.
  7. Use a new nameplate only after three polls in a row report it. A change of more than 10 percent is a different pack, such as an added expansion module: clear the windows and start again, because runs of the old pack would read as wear on the new one. Tag each weekly point with its nameplate and method so a trend compares like with like.
  8. Label confidence from the number of windows behind the published value (under 6 low, under 12 medium, otherwise high), then lower it for each known way that count overstates it: one direction only, a median absolute deviation of 5 or 10 percent within a direction, charge and discharge power 4 or 6 times apart, mostly PV-charged charge windows, and counting drift of 2 or 5 percent. Name the checks that lowered it in confidence_limits. The thresholds come from a simulation campaign; they are not a calibrated error bar.

Expected error, stated as a bound rather than a calibration ​

These are limits, not a claim that a particular Marstek pack was checked on a DC meter. No real device was available for this change.

  • Quantization. One state-of-charge count on a 20-point window is about 5 percent. A window that starts and ends on the first poll after a step leaves only how far state of charge moves in one poll. A simulated 23-point discharge at 1 kW on a 4600 Wh pack, whole percents, a 30 second poll and a random starting phase put the single window within 0.7 percent of the true capacity at the 95th percentile, against 4.5 percent when the window started on the first poll. A 60 second poll doubles that residual. This is arithmetic on synthetic traces, not a published method; no paper that times windows on state-of-charge steps was found.
  • Efficiency, one direction only. The absolute watt-hours scale by η_true / 0.93 on discharge and by 0.93 / η_true on charge. A real one-way efficiency of 0.90 instead of 0.93 is about a 3 percent bias. A larger miss is a larger bias. The integration has not measured it on Marstek hardware. Independent tests of the Venus E 3.0 report round trips of about 80 to 85 percent (heise, technikblog.ch, energienerds, techtest.org), about 0.88 to 0.92 one way with standby included; Marstek states only a maximum with no load condition. Victron's 99 percent figure is coulombic efficiency at a DC shunt, not this AC port.
  • Efficiency, both directions. The geometric mean cancels a factor shared by both directions. If the two real one-way efficiencies differ, the residual factor is the square root of their ratio. A few percent of difference between charge and discharge leaves a residual of about half that, in relative terms. The two medians are discharge_median_wh and charge_median_wh. implied_round_trip_efficiency is the round trip those medians imply under the 0.93 assumption. Inverters lose more at low power, so charging at 2500 W and discharging at 300 W left 2 to 3 percent on a typical inverter curve and about 5 percent on a poor one in simulation; that power ratio lowers confidence.
  • Self-consumption. The unit's own draw is not in the reported watts. It makes discharge windows read low and charge windows read high. 15 W at 800 W both ways gave -1.6 and +2.0 percent, and -0.2 percent after the geometric mean. At unequal power a residual remains: about -1.5 percent charging at 2500 W and discharging at 300 W, about +2.6 percent the other way round. The implied round trip carries both biases.
  • PV on Venus A and D. Derating the whole derived battery reading used to multiply PV watt-hours by 0.93. The factor now applies only to the AC port. A device bat_power is unchanged. pv_share on each stored window is the fraction of the battery-power integral that PV covered. PV watts enter with no conversion loss, so a PV reading error passes straight into charge windows: 5 percent high gave about +4 percent. Mostly PV-charged charge windows cap confidence at medium.
  • BMS state of charge. This can dominate the arithmetic. If the percentage does not move when the pack has faded, the sensor will not move either. The sensor measures "watt-hours per reported state-of-charge point", which equals chemical capacity only when the reported percentage is an honest fraction of that capacity.
  • Counting drift and the reset at full. A BMS that counts 6% too little charge resets with a jump of about six points at full. On simulated packs (30 days, six seeds per case) that drift put the published capacity 3.0% high; over-counting discharge by 6% put it 3.0% low. A creep or a hold at 99% added nothing beyond the drift itself, because the median ignores the one window that contains the reset. The jump cannot correct the number: both counters jump upward but bias it in opposite directions. It bounds it. The pooled ratio of corrected points to points moved (soc_drift_bound_pct) read 3.1 to 3.3% against that 3.0% error, and 0.0% on every honest pack. It is a guide, not a guarantee: a counter 4% high that holds at 99% gave 1.0 to 1.4% against a 2.0% error, because part of each hold falls outside the 15-point approach. A counter divided by the nameplate instead of the faded capacity never jumps and was 11% high with a bound of 0.0%; no reading of the percentage can see that. The vendor Control 150 firmware, run in the emulator against a BMS counter with these errors (can_peers.py --bms-*), passes the BMS percentage straight to ES.GetStatus: a jump arrived as 93 to 100% in one poll, and at a 99% hold the firmware kept charging until the BMS reported 100%. The integration's own parser and estimator, fed those polls, recorded the jump at 7 points, the hold at -5.9 points and an honest full charge as none. A creep went unrecorded there because no capacity was published yet; replayed with one, it read 7.1 points. All of this assumes the counter resyncs at full. A charge counter that over-counts and stops charging at its own 100% never does: the bound stays at 0.0%, the estimate reads 2 to 3% low, and the implied round trip 3 to 5 points high. At a bound of 5% or more the card shows the band as Uncertain.
  • Temperature and rate. Not corrected. Cold weather and very high power make a session read low. Peukert is not applied.
  • Not a nameplate test. A lab capacity is a full charge and discharge at a stated temperature and rate. These windows are whatever the house was doing, provided the window was long and clean.

The number to watch over months is the trend. A single reading, especially before both charge and discharge have contributed, is not a warranty measurement.